Micro-Fix

Eddy current inspection meathod with experience.

日本語

English

Eddy current tapped hole inspector MTD-100

Eddy current tapped hole inspector MTD-100

General purpose model

  • Detect tapped hole abnormality such as less effective thread length, or wrong pilot hole diameter
  • Easy and reliable use in any production site where using cutting oil/ fluid
  • Select from either single or multi-channel Maximum 16 sensors can be connected to multi channel

Contactless sensor
Application soft is available for data collection or automatic threshold calculation.
Standard size are available From M2.6 to M12
Model MTD-100
Power supply DC24V 24W
Input / output Input 11 points / Output 8 points
Environment in use Temp 0℃ - 40℃ Humidity 0 - 80%RH ( No condensation )
Case dimensions 260 x 94 x 230 ( W x H x D )